Physics of the Universe · Lesson 8.6 · Unit 8 · HS-PS3-3
Read the opening paragraph and the "The key ideas" box on the lesson page. In your own words, restate each idea below.
A transformer has a primary and a secondary coil on a shared iron core.
An alternating current in the primary produces a changing flux, which induces an emf in the secondary.
\( \dfrac{V_s}{V_p} = \dfrac{N_s}{N_p} \), so the voltage ratio equals the turns ratio.
Energy conservation gives \( V_pI_p = V_sI_s \) for an ideal transformer, so stepping voltage up steps current down.
Transformers cannot work with direct current, since a steady current produces no changing flux.
Real efficiency exceeds 98 percent in large units, with losses from coil resistance, eddy currents and core magnetization.
Read the "Worked example" box. Then, without looking back, try writing your own answer below.
(a) Find the secondary turns needed to step 120 V down to 6.0 V with a 2000-turn primary. (b) A station generates 5.0 MW at 25 kV and steps it to 400 kV. Find both currents and the turns ratio. (c) Explain why a transformer will not work on direct current. (d) Explain where a real transformer's energy is lost and how each loss is reduced.
In two or three sentences, explain this lesson's main idea to someone who has not read it.